Apimaye vs. Primal Bee: Insulation Claims Compared
R-6.93
Polyurethane wall insulation, independently tested to EN 12667. Tested by TEBAR, a lab accredited by TÜRKAK (No. AB-0302-T). Report No. R1600463.
The report is a scanned PDF without selectable text. Its key details are transcribed on this page.
Foam has limits. Primal Bee's published R-values would need two to six times more foam than its hive has.
- 65 mm foam side wall, claimed R-25: estimated at about R-11
- Thinnest walls, 30 mm: estimated at about R-5
- Foam-and-air lid, claimed R-140: estimated at about R-25
- Foam-and-air bottom, claimed R-75: estimated at about R-20
- Whole hive, claimed R-50: estimated at about R-12 to R-13
Estimates use R-4.3 per inch, the highest minimum rating for EPS foam in the U.S. standard (ASTM C578 Type XV).
Updated . Primal Bee's claims checked on .
R-50 and R-6.93 measure different things
Primal Bee advertises its EPS foam hive as R-50. Apimaye publishes R-6.93. The two numbers aren't arrived at the same way:
- Apimaye's R-6.93 is a lab result for a 31.3 mm (1.23 in) sample of the polyurethane foam inside Apimaye's walls, tested by an accredited lab to a named standard.
- Primal Bee's R-50 is its own average across the whole hive: the walls, a lid with a 175 mm air chamber, and a bottom board with a 106 mm air chamber. We couldn't find a published lab report verifying R-25 for the side walls or R-50 for the assembled hive.
Primal Bee's comparison page (opens in a new tab) acknowledges the difference, saying its figure is "measured across the top cover, nest walls, and bottom board — not one foam wall." It then sets its R-50 against a "basic insulated example" at about R-7 and marks itself the winner on thermal specification. Its technical guide (opens in a new tab) lists Apimaye at "About R-6.93" in the same table as its own R-50. A fair comparison puts wall against wall, which is what the rest of this page does.
What each number covers
Apimaye: R-6.93
- What the number covers
- A 31.3 mm sample of the wall foam
- Source
- TEBAR, an accredited lab (TÜRKAK)
- Test standard
- EN 12667
- Air chambers in the number
- None; the sample is solid foam
- Lab report published
- Yes, you can download it
Primal Bee: R-50 (claimed)
- What the number covers
- An average across walls, lid and bottom, counting air chambers
- Source
- Primal Bee's own figure; no independent lab named
- Test standard
- None named; its patent describes a heat-loss method
- Air chambers in the number
- Yes, and the totals need far more from them than standard tables allow
- Lab report published
- None we could find
R-value in plain English
R-value measures how well something slows heat transfer. A higher R-value means heat moves through more slowly: the hive holds its warmth in winter and keeps outside heat out in summer. Think of a winter coat: every fabric has a fixed insulating value per inch, so two coats made of the same fabric only differ by how thick they are. A thin coat can't insulate like a thick one just because the tag says so.
Hive foam works the same way. Once you know the foam and its thickness, you know roughly how well the wall insulates. Three questions to ask any hive maker:
- What exactly was measured? The wall itself, or an average across the whole hive?
- Who measured it? An accredited lab, using a named test standard?
- Can I see the report?
One more thing to watch: R-values come in two scales. U.S. R-values (ft²·°F·h/BTU) are about 5.68 times larger than metric ones (RSI, in m²·K/W), so Apimaye's lab result is R-6.93 in U.S. units and RSI 1.22 in metric. Every number on this page is in U.S. units. When you compare hives, make sure both numbers use the same scale.
Claimed R-values vs. our estimates for the foam listed
Longer bars mean slower heat transfer. Estimates use the ASTM C578 Type XV benchmark, R-4.3 per inch.
Side walls (65 mm)
Lid
Bottom
Whole hive
The claims, and what the foam can actually do
Primal Bee's insulation article (opens in a new tab) lists the parts behind its R-50: side walls of 65 mm EPS, a front wall of 84 to 127 mm, a lid made of two 70 mm foam layers around a 175 mm air chamber, and a 110 mm insulated bottom board with a 106 mm air chamber above it, under the frames. Its getting-started guide (opens in a new tab) says the walls are 30 to 70 mm thick, so parts of the hive are less than half as thick as the 65 mm side walls.
Here's what those thicknesses come to at the ASTM C578 Type XV benchmark of R-4.3 per inch.
Swipe the table sideways to see all columns →
| Hive part | Claimed | Estimated at R-4.3/in | Foam Primal Bee lists | Foam needed to reach the claim |
|---|---|---|---|---|
| Side walls | R-25 | About R-11 | 65 mm (2.6 in) EPS | 148 mm (5.8 in) |
| Front wall | R-25 | About R-14 to R-22 | 84 to 127 mm (3.3 to 5 in) EPS | 148 mm (5.8 in) |
| Thinnest walls | Not stated | About R-5 | 30 mm (1.2 in) EPS | |
| Lid | R-140 | About R-25 | Two 70 mm EPS layers + 175 mm air chamber | 827 mm (32.6 in) of foam |
| Bottom | R-75 | About R-20 | 110 mm insulated bottom board + 106 mm air chamber | 443 mm (17.4 in) of foam |
| Whole hive | R-50 | About R-12 to R-13 | All of the above |
Foam counted at R-4.3 per inch, the minimum rating for the densest EPS type (Type XV) in ASTM C578. For the bottom, we assume the full 110 mm board thickness is EPS insulation; Primal Bee hasn't published how much of it is foam, so this assumption favors Primal Bee. Each air chamber counted at R-1, our assumption; standard tables put sealed air spaces with ordinary surfaces at about R-0.8 to R-1.6. Whole hive weighted by surface area, explained below. Sources are listed at the bottom of the page.
How the math works
A foam board's R-value is its thickness times its R-value per inch. For EPS foam, the U.S. standard (ASTM C578) lists a minimum of R-4.3 per inch for Type XV, its densest type at 3.0 lb/ft³ (about 48 kg/m³). In the standard, extra density mostly buys strength: going from Type IX at 1.8 lb/ft³ to Type XV at 3.0 lb/ft³ only moves the minimum rating from R-4.2 to R-4.3 per inch.
Primal Bee claims a higher-density formulation, over 90 kg/m³, nearly twice as dense as Type XV. Without a published thermal-conductivity measurement for that specific foam, its exact resistance is unknown. We therefore model performance at R-4.3 per inch and test a more favorable R-5 scenario, with each air chamber counted at R-2. In that scenario the side walls come out at about R-12.8, the lid at R-29.6 and the bottom at R-23.7. Cold weather helps foam a little, about 10% at a 40°F average temperature according to the EPS Industry Alliance. That's still nowhere near R-25, R-140 or R-75.
For scale: a 65 mm wall at R-25 would need foam conducting heat about 40% less than still air, a level reached by vacuum panels and aerogels, not air-filled foams like EPS.
Put another way: to reach R-25, a foam wall needs about 5 to 6 inches of EPS. To reach R-140, a lid would need 28 to 33 inches of solid foam.
How much foam the claims would need, drawn to scale
Side walls have 65 mm of foam; R-25 needs 148 mm. The bottom board is 110 mm thick; R-75 needs 443 mm. The lid has 140 mm; R-140 needs 827 mm, about 33 inches.
EPS at R-4.3 per inch. Air chambers aren't drawn; we count each at about R-1.
What the air chambers can add
The two biggest numbers, the R-140 lid and the R-75 bottom, lean on air chambers. Counting a sealed air space is standard engineering practice. What it's worth depends on which way heat flows through it, the temperature, and whether its surfaces are reflective. For sealed air spaces up to 3.5 inches deep with ordinary, non-reflective surfaces like foam, the ASHRAE Handbook's table gives about R-0.8 to R-1.0 when heat flows up, as it does through a lid, and about R-1.0 to R-1.6 when heat flows down, as it does into a bottom chamber.
A deeper gap doesn't add much. When heat flows up, the air circulates and carries heat across. Even when the air stays still, heat radiates straight across the gap, which keeps an air space with ordinary surfaces to roughly R-2 or less, however deep it is. Only shiny, foil-faced air spaces go much higher, and we found no mention of reflective surfaces in Primal Bee's description of its hive.
We counted each air chamber at R-1, and at R-2 as a generous check. Either way, the shortfall is huge. For the lid to reach R-140, its air chamber would have to supply about R-116, because the foam only gives about R-24. For the bottom to reach R-75, its air chamber would have to supply about R-56.
Primal Bee describes the bottom air chamber as the space between the varroa tray and the bottom of the frames, and the hive has a screened bottom board for ventilation. If that space is open to the airflow, it's worth less than a sealed air space, so our count is generous.
The averaging problem
A single whole-hive R-value sounds scientific, but heat doesn't average that way. Heat leaves through every square inch of the hive, and the walls are most of the surface: on a hive 15.7 × 23.4 × 58.2 inches, the four sides make up about 86% of the outside area. A very thick lid can't make up for walls that let heat through.
Engineers average heat loss, not R-values. Done that way with Primal Bee's own numbers (R-25 walls, R-140 lid, R-75 bottom), the whole hive comes out around R-28, not R-50. With our estimates for the foam listed, it's about R-12 to R-13, or about R-14.4 even if the back wall is as thick as the front. That's an estimate from published dimensions, not a measurement, and it would be lower where walls are as thin as 30 mm. It also counts only heat passing through the walls, lid and bottom. A real hive loses more through the entrance, ventilation and gaps between boxes, so an assembled hive would do worse, not better. The full calculation is under Whole-hive calculation, in How we checked. A plain average of R-25, R-140 and R-75 is R-80, so it isn't clear how R-50 was calculated.
Red flags to watch for
- No lab report, and no method shown. A measured R-value should come with a lab report naming the test standard, the sample and the conditions. A calculated R-value can be legitimate too, but the maker should show its assumptions and math. Primal Bee's science page (opens in a new tab) describes its own thermal-camera photo as "not one shared laboratory R-value test," and we couldn't find how its R-50 was calculated.
- One whole-hive "average". A single big number can hide thin walls behind a thick lid.
- Big numbers for air chambers. Counting an air space is normal, but with ordinary surfaces it's worth about R-1 to R-2. A total that needs far more than that from the air deserves a question.
- Numbers that change from page to page. Its technical guide (opens in a new tab) lists the nest side walls at "about R-25" in a table, then says in its FAQ that "the nest walls average about R-50." Its getting-started guide (opens in a new tab) says "the average R-value of the walls is around 50" and that "the outer lid exceeds R-125," while its insulation article gives R-25 walls and an R-140 lid. The same article calls the air space under the nest a "90mm air cushion" in one place and a 106 mm air chamber in another. Wall thickness is "30 to 70 mm" on one page and up to 127 mm on another.
- A patent offered as proof. Primal Bee's U.S. patent (opens in a new tab) describes a whole-hive heat-loss test, with a heater standing in for the colony, and that's a reasonable way to compare hives. But a patent protects an invention; it isn't a performance test. The patent office doesn't test or certify a hive's R-value, and we found no R-values in the patent.
An open offer: if any hive maker publishes an accredited lab report for its R-values, send it to support@apimaye-usa.com and we'll update this page.
Where a thicker foam wall does beat Apimaye
Here's the part most comparison pages leave out: thickness matters. A 65 mm EPS wall, estimated at about R-11, should insulate better than an Apimaye side wall at our lab-tested R-6.93.
Inch for inch, Apimaye's polyurethane foam measured R-5.6 per inch in the lab. Against the ASTM C578 minimum for the densest EPS, adjusted to the same test temperature, that's roughly 20% better per inch. Primal Bee hasn't published a conductivity measurement for its own foam, so we can't give an exact head-to-head figure, but even at R-5 per inch, better than any EPS type in the standard, Primal Bee's foam would still trail Apimaye's measured R-5.6. The EPS wall is simply about twice as thick. We'd rather tell you that than pretend otherwise.
Insulation per inch of material
Longer bars mean slower heat transfer. Test temperatures differ; see How we checked.
Apimaye polyurethane foam (lab-tested)
ASTM C578 Type XV EPS (minimum rating)
Pine wood
Wood ranges from about R-1.0 to R-1.4 per inch.
Here's what you get with Apimaye:
- A number you can check. R-6.93, measured by an accredited lab, with the full report published.
- A hard plastic shell. The foam is sealed inside UV-stabilized, food-grade plastic. Bare EPS hives are foam on the outside, and Primal Bee includes instructions for painting its hive. See how bare foam holds up.
- Standard frames. Ergo brood boxes take standard 10-frame Langstroth frames, and 10-frame wooden boxes stack on top. Primal Bee's hive uses its own brood frames, and Primal Bee says standard Langstroth frames don't fit the nest.
- 6 to 7 times the insulation of a wooden hive. Softwood lumber is about R-1.0 to R-1.4 per inch, so a 3/4-inch pine wall is roughly R-1.
Insulation is only part of the picture. Foam hives also have to stand up to wax moths, mice, sun and hive tools. See hard plastic vs. foam (EPS) beehives, with photos of wax moth damage.
How much does the extra R-value matter?
Insulation has diminishing returns. Heat loss through a wall is proportional to 1 divided by its R-value, so the first few R-values do most of the work.
Heat lost through the wall, compared with a wooden hive
Shorter bars lose less heat. A 3/4-inch wood wall (about R-1) = 100%.
Wooden hive wall (about R-1)
Apimaye wall (R-6.93)
65 mm EPS wall (estimated R-11)
Going from a wooden wall to Apimaye's R-6.93 cuts the heat lost through the walls by about 86%. A 65 mm EPS wall cuts it by about 91%. The extra 5 points are real, but small.
The walls also aren't the only way heat escapes. The entrance, ventilation, the bottom board and the joints between boxes don't change when the walls get thicker, so the whole hive gains even less. In measurements of complete hives (Mitchell, 2016), wooden hives lost heat at about 2.6 W/K and EPS foam hives at about 0.9 to 1.3 W/K. That's 2 to 3 times better than wood, less than the difference in their wall insulation would suggest.
What the research shows: a 2026 USDA-ARS study found polyurethane-insulated hives warmer and drier than wooden ones, and over the season the wooden hives lost 4.8 kg while the polyurethane hives lost 0.8 kg. We haven't found any study that compares insulated hives at R-6 and R-11, so there's no published evidence that colonies do better at one than the other. The big step is from wood to a well-insulated hive.
Apimaye's lab test
| Laboratory | TEBAR Test Certification R&D Inc., Istanbul, accredited by TÜRKAK, the Turkish Accreditation Agency (No. AB-0302-T) |
|---|---|
| Test standard | EN 12667, the European standard for measuring the thermal resistance of insulation (heat flow meter method). Thickness measured to EN 12085. |
| What was tested | The polyurethane foam (PUR) used as the core insulation between Apimaye hive walls, brand name Apimaye, made in 2016. One 297 × 297 mm specimen (No. N1600254), 31.3 mm (1.23 in) thick, sent to the lab by the manufacturer, Yıldırım Plastik of Istanbul. |
| Test conditions | 10°C (50°F) mean temperature, 20°C difference across the sample, heat flow of 16.4 W/m². Sample density 60.55 kg/m³, conditioned at 23 ± 5°C. No change in thickness, length or width during the test. |
| Result | Thermal resistance 1.22 m²·K/W = R-6.93 (US units). Thermal conductivity 0.0257 ± 0.001 W/m·K (95% confidence). |
| Report | No. R1600463, 5 pages. Tested June 22–23, 2016, issued June 24, 2016. Signed by K. Çatkın, laboratory technician, and E. Kara, head of the testing laboratory. |
To be clear about what this covers: the lab tested the wall insulation itself, not an assembled hive, and that's the number we publish. We don't add air spaces or average it across the lid and floor to make it bigger. More about the test or download the report (PDF). The PDF is a scanned image without selectable text; the table above transcribes its key details.
Frames are optional: $620 without frames, or $790 with wood frames and foundation for all four boxes. Free ground shipping in the contiguous U.S. Or compare all Ergo hive sets.
Frequently asked questions
What is R-value?
R-value measures how well a material slows heat transfer. A higher R-value means heat moves through more slowly. For foam, it depends on the type of foam and its thickness, so a thin wall can't match a thick wall made of the same foam.
Can a 65 mm foam wall reach R-25?
Extremely unlikely. At R-4.3 per inch, the ASTM C578 minimum for Type XV EPS, a 65 mm (2.6 inch) wall comes to about R-11, and even at a favorable R-5 per inch it's about R-12.8. To reach R-25, the foam would have to conduct heat about 40% less than still air, which vacuum panels and aerogels can do but air-filled foams like EPS can't.
Does denser EPS foam insulate better?
Not much, as far as published ratings show. In ASTM C578, the minimum rating rises only from R-4.2 per inch for Type IX EPS at 1.8 lb/ft³ to R-4.3 for Type XV at 3.0 lb/ft³; the extra density mainly adds strength. We found no published thermal-conductivity measurement for Primal Bee's 90+ kg/m³ foam.
How much R-value does an air chamber add?
It depends on the direction of heat flow, the temperature and the surfaces. For a sealed air space with ordinary, non-reflective surfaces, the ASHRAE Handbook's table gives about R-0.8 to R-1.6, and a deeper gap adds little. Only reflective, foil-faced air spaces go much higher.
Is a patent proof of an R-value?
No. A patent protects an invention; it isn't a performance test. The patent office doesn't test or certify a hive's R-value. Ask for a lab report, or a calculation that shows its work.
Which insulates better, Apimaye or a thick EPS foam hive?
A thick EPS wall can have a higher R-value than an Apimaye wall: about R-11 for 65 mm of EPS, versus Apimaye's lab-tested R-6.93. Apimaye's foam insulates roughly 20% better per inch than the ASTM benchmark for the densest EPS, its number is verified by an accredited lab, and the hive has a hard plastic shell and takes standard 10-frame Langstroth frames.
Is an R-11 wall much better than R-6 for the bees?
Not by much. Compared with a wooden wall, R-6.93 cuts heat loss through the walls by about 86% and R-11 by about 91%. Other heat losses, like the entrance and ventilation, stay the same. We haven't found any study showing colonies do better at R-11 than at R-6.
How do I check any hive's R-value claim?
Ask for the lab report. It should name the lab, the test standard, what was tested and how thick it was, and the result. If the number is calculated rather than measured, ask for the assumptions behind it. If the number covers "the whole hive," ask what the walls alone are rated.
How we checked
We took the claimed R-values and thicknesses from Primal Bee's website on November 4 and 5, 2026: its insulation article, its technical guide, its getting-started guide, its comparison page and its product page. Foam ratings come from the ASTM C578 table published by the EPS Industry Alliance, air space values from the ASHRAE Handbook of Fundamentals table for sealed air spaces, and wood values from the American Wood Council, which cites the USDA Wood Handbook. We counted foam at R-4.3 per inch, the ASTM C578 minimum for Type XV EPS (and at R-5 per inch as a more favorable scenario) and each air chamber at R-1 (and at R-2 as a generous check). We counted the full 110 mm bottom board as foam, since Primal Bee hasn't published how much of it is foam. For the whole hive, we weighted the walls, lid and bottom by their share of the outside surface, using the hive's listed outside dimensions, and averaged heat loss rather than R-values. These are estimates from published numbers, not a lab test of the hive.
Whole-hive calculation
| Face | Outside area | R-value used |
|---|---|---|
| Two long sides, 23.4 × 58.2 in | 2,724 sq in (51.5%) | R-11 (65 mm EPS) |
| Back, 15.7 × 58.2 in | 914 sq in (17.3%) | R-11 (65 mm EPS) |
| Front, 15.7 × 58.2 in | 914 sq in (17.3%) | R-14 to R-22 (84 to 127 mm EPS) |
| Lid, 15.7 × 23.4 in | 367 sq in (6.9%) | About R-25 (140 mm EPS + air chamber) |
| Bottom, 15.7 × 23.4 in | 367 sq in (6.9%) | About R-20 (110 mm board counted as EPS + air chamber) |
| Whole hive | 5,286 sq in | About R-12.3 to R-13.0 |
To combine the faces, divide each face's area by its R-value, add those up, and divide the total area by that sum. This averages heat loss, not R-values.
Assumptions: the front is the 15.7-inch face (the entrance end), and only the front is 84 to 127 mm thick, as Primal Bee's insulation article lists it; the back is counted like the 65 mm side walls. If the back is as thick as the front, the whole hive comes out at about R-12.9 to R-14.4. Primal Bee says some walls are as thin as 30 mm but doesn't say which, so those sections are left out; including them would lower the result. Even if we stack every generous assumption at once (R-5 per inch, R-2 for each air chamber, and both front and back walls at the full 127 mm), the whole hive still comes out under R-17, not R-50.
Test temperatures: Apimaye's foam was tested at a 10°C (50°F) mean temperature. The ASTM C578 rating for EPS is a minimum at a 75°F mean, and the EPS Industry Alliance says EPS insulates about 10% better in cold weather, so at a 50°F mean the EPS benchmark would be roughly R-4.6 per inch. Our "roughly 20% better per inch" compares Apimaye's R-5.6 with that R-4.6.
Sources
- EPS Industry Alliance: ASTM C578 Thermal Performance Table (opens in a new tab)
- EPS Industry Alliance: Polystyrene Foam Insulation in Long-Term Building Applications: Effective R-values (opens in a new tab)
- ASHRAE Handbook of Fundamentals, reproduced by Engineers Edge: Thermal resistances of well-sealed air spaces (opens in a new tab)
- American Wood Council: What is the thermal conductivity of wood? (opens in a new tab)
- Mitchell, International Journal of Biometeorology (2016): Ratios of colony mass to thermal conductance of tree and man-made nest enclosures of Apis mellifera (opens in a new tab)
- Alburaki et al., USDA-ARS, Journal of Economic Entomology (2026): Implications of the hive materials and mtDNA haplotypes on honey bee thermoregulation and colony weight (opens in a new tab)
- USDA-ARS, Journal of Apicultural Research (2021): Polyurethane vs. wooden hives in winter (opens in a new tab)
- TEBAR Test Certification R&D: Apimaye insulation test report No. R1600463 (PDF, scanned image)
- Apimaye: Hard plastic vs. foam (EPS) beehives: durability and care
- Apimaye: Insulated Beehive R-Value: R-6.93, Lab-Tested
- Primal Bee: Beehive insulation: how Primal Bee reaches R-50 (opens in a new tab)
- Primal Bee: The science behind Primal Bee: thermal efficiency explained (opens in a new tab)
- Primal Bee: How Primal Bee works: start here (opens in a new tab)
- Primal Bee: The best insulated beehive (comparison page) (opens in a new tab)
- Primal Bee: Science: patent, research and field evidence (opens in a new tab)
- U.S. Patent 11,375,697: Rational hive structure (opens in a new tab)
- Primal Bee claims checked November 4 and 5, 2026; archived copies saved on the Internet Archive's Wayback Machine